• Air-Conditional Chiller Pump Controller B605D Series 380V
  • Air-Conditional Chiller Pump Controller B605D Series 380V
  • Air-Conditional Chiller Pump Controller B605D Series 380V
  • Air-Conditional Chiller Pump Controller B605D Series 380V
  • Air-Conditional Chiller Pump Controller B605D Series 380V
  • Air-Conditional Chiller Pump Controller B605D Series 380V

Air-Conditional Chiller Pump Controller B605D Series 380V

Application: High-performance Transducer, Three Phase Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Principle of Work: V/F Control Transducer
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Air-Conditional Chiller Pump Controller B605D Series 380V pictures & photos
Air-Conditional Chiller Pump Controller B605D Series 380V
US $165-8,272 / Piece
Min. Order: 1 Piece
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Guangdong, China
Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (31)

Basic Info.

Model NO.
B605D
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type
Brand
Bedford
Color
Blue
IP
20
Warranty
1 Year
Certificate
Ce, ISO 9001, ISO14001
Voltage
330~440V
Transport Package
Carton
Trademark
BEDFORD
Origin
Guangzhou, China
HS Code
9032899090
Production Capacity
5000 Pieces /Month

Packaging & Delivery

Package Size
45.00cm * 45.00cm * 45.00cm
Package Gross Weight
10.000kg

Product Description

Air-Conditional Chiller Pump Controller
B605D Series 380V (IP20)

Air-Conditional Chiller Pump Controller B605D Series 380V
Product Description:
B605 series controller is specially designed for central air-conditioning water circulation system to realize constant pressure differential control. It can confirm the system to adapt to the change of air-conditioning load, with the advantage of rapid reaction, little influencing on temperature and humidity, ensuring the balance of the system, effecient energy-saving and so on.

Input Voltage/Output Power Range:
Single phase 380V input,3 phase 0-380V output: 1HP-470HP(0.75KW-350KW)

Applications:
Central air conditioning circulating system
          


Features:
1. Relay Output: 2 Outputs.
2. Professional design based on users' needs, suitable for differential pressure control, simple operation.
3. Running automatically when power on.
4. Programmable Analog Input:
   AI1:0~10V or 0~20mA input
   AI2:0~10V or 0~20mA input
5. Multi-Pump Control: can realize 1 master and 5 slaves combine work at most.
6. Constant Differential Pressure Control: PID, control based on feedback source of (AI1-AI2).
7. Alternate running balance every pump's running time, prolong service life of the pump.
8. Verious of water supply fault alarm functions:high pressure, low pressure, low level, transducer error etc.
9. As many as 22 kinds of fault protection functions: over current, over voltage, low voltage, phase failure, over load etc.
                      Air-Conditional Chiller Pump Controller B605D Series 380V


Dimension:
Air-Conditional Chiller Pump Controller B605D Series 380V
Air-Conditional Chiller Pump Controller B605D Series 380V

Keypad Description:
Air-Conditional Chiller Pump Controller B605D Series 380V

Daily Maintenance:

In order to prevent the fault and prolong the service life of the controller, user shall daily
inspect the controller. The following table indicates the inspection content:
Air-Conditional Chiller Pump Controller B605D Series 380V


 Replacement of Wearing parts:

  Fans and electrolytic capacitors are wearing parts; please make periodic replacement to ensure
long term, safety and failure-free operation. The replacement periods are as follows:
1. Fan: must be replaced when using up to 20,000 hours;
2. Electrolytic capacitor: must be replaced when using up to 30,000~40,000 hours.

 

Why Always BEDFORD???

 

1.Professional--21 years Professional solar inverter  Export, 9 years manufacturer ExperiencePatent products

2.Reliable--6 years Alibaba Gold Supplier

 

3.Hi-tech--Advanced R&D Team

 

4.Certifications--Applied with CE, ISO 9001, ISO14001

 

5. Good quality--BEDFORD Brand, Patent products.

 

 

Can't wait to know more about our Company, Products, Price, Packing, Shipping? Dear FriendsLet's talk NOW !!!!!

 

 

Website:gzbedford.en.made-in-china.com

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Air-Conditional Chiller Pump Controller B605D Series 380V pictures & photos
Air-Conditional Chiller Pump Controller B605D Series 380V
US $165-8,272 / Piece
Min. Order: 1 Piece
Diamond Member Since 2009

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
142
Year of Establishment
2007-04-10