Customization: | Available |
---|---|
Nature of Source Flow: | Passive inverter |
Phase: | DC Input, 3pH 220V or 380V Output |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Product Description
This product is specially desgined for solar pv pumping system and aiming at environmental protection and economical market, no need battery and extral maintenance. Based on the core control arithmetic(DSP) of B503 vector control inverters, combined with the control requirements of PV water pump application. The function of MPPT,Sleep Mode, Multiple Water Level Control and other control protection functions can ensure normal operation of water pumps .According to the customers requirements , it can switch to the power grid/AC supply.
2. Characteristics
DC/AC Input Compatible DC: Solar PV Power Supply AC: Dissel Generator or Power Grid Supply
No Need Battery
Environment-Friendly, Economical, No need additional maintenance
Optimized MPPT Arithmetic, DSP(Digital Signal Processor),Accuracy Reached 99% and above.
Multi-Water-level Control
Low Water Level,High Water Level Control, Water-Level Detecting Judgement.
Abundant Protection Functions
Featured with Protection Functions of Lightning-proof, Over-voltage,Over-current, Over-load,etc.
Sleep Mode
Automatically sleep in poor light , Automatically awake in bright light, unattended operation
3.Schematic Map
4.Power supply
5.Solar Cell Array and AC Power Supply 5.Solar Cell Array and AC Power Supply
Note: if there is no protection diode connected to the end of the photovoltaic DC input, it is forbidden to close the switches (Q1 and Q2) at the same time, otherwise, it will damage the module of photovoltaic cell
The notes below should be considered for the AC debug
1. Power On Sequencing:Firstly open Q2 ,and then close Q1;
notice:
(1) If there is no protection diode connected to the port of input-bus, it is forbidden to close photovoltaic cell switch "Q1" and input switch of power grid "Q2" at the same time, otherwise it will damage the module of photovoltaic cell
(2) When need to transform the power supply mode from power frequency to photovoltaic cell; you only need to turn off "Q1"firstly and then close "Q2".
Specification | Specification | ||
Output 3AC 380V | Output 3AC 220V | ||
Maximun input DC voltage | 800V DC | Maximun input DC voltage | 410V DC |
Recommended DC input voltage range | 400 ~ 720V DC | Recommended DC input voltage range | 220~370V DC |
Recommended input working voltage | 540V DC | Recommended input working voltage | 305V DC |
The number of input port | 1 | The number of input port | 1 |
Rated output voltage | 3AC 380V | Rated output voltage | 3AC 220V |
Output frequency range | 0~400Hz | Output frequency range | 0~400Hz |
Cooling method | Air cooling | Cooling method | Air cooling |
Altitude | This controller should be installed with altitude of lower than 1000m .It will be degraded when the altitude higher than 1000m.For details ,rated output current should be degraded 1% for every 100m | Altitude | This controller should be installed with altitude of lower than 1000m .It will be degraded when the altitude higher than 1000m.For details ,rated output current should be degraded 1% for every 100m |
Standard | CE | Standard | CE |