Application: General Transducer
Output Type: Triple
Principle of Work: PLC Control
Switch Mode: PWM Control
Main Circuit Type: Current
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Rating: 5.0/5
Guangdong, China
Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (31)

Basic Info.

Model NO.
B603
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Current Variable-Frequency Drive
Function
Booster Pump Control Appication
Brand
Bedford
IP Grade
IP20 or IP54
Control
Pressure Control
Linkage
Max.6 Pumps
Transport Package
Carton/Ply-Wooden Case
Specification
CE,ISO9001,14001,GB/T12668.2-2002&GB12668.3-2004
Trademark
BEDFORD
Origin
Guangzhou, China
Production Capacity
2000/Month

Product Description

Pump Variable Frequency Drive
Pump Variable Frequency Drive
Pump Variable Frequency Drive
This Series Power Range:

Single phase 220-240V 1HP-3HP(0.75KW-2.2KW)
Three phase 220-240V 5HP-75HP(3.7KW-55KW)
Three phase 380-440V 1 HP-470HP(0.75KW-350KW)
Pump Variable Frequency Drive
Technology Features
Input & Output
Input Voltage Range: 380/220V± 15%
Input Frequency Range: 47~63Hz
Output Voltage Range: 0~rated input voltage
Output Frequency Range: 500Hz

I/O Features
Digital Switch Input: 3 input
Programmable Analog Input: AI1: 0~10V or 0~20mA input;
AI2: 0~10V or 0~20mA input
Relay Output: 2 Output

Function Characteristics
Multi-Pump Control: Can realize 1 master and Max. 5 auxiliaries combine work

Sleep Function: Sleep down when have no water consumption, to earn a better energy saving

Freeze-Proofing Function: Suitable to low temperature area, prevent pump from freezing

Anti-clogging Function: Take precaution against pipe clogging and clean the pipe dirt

Power On Restart: Running automatically when power on

Master Fault Shift Automatically: Keep on working when the master break down

Alternate Running: Balance every pump's running time, prolong service life of the whole unit machine

Day-Part Function: 3 independent day-part control, up to 7 day-part achieved when define separated

Two Running Mode: Synchronous control mode, master-slave control mode

Terminal Control Mode: Terminal Run/Stop, Manual/Auto Control, Electronic Contact Gauge Control

Various of water supply Fault Alarm Function: High-Pressure, Low-Pressure, Low-Level, Transducer Error etc.

As many as 22 kinds of fault protection function: Over-Current, Over-Voltage, Low-Voltage, Phase-Failure, Over-Load etc.
 