Variable Frequency Drive VFD Constant Pressure Water Pump Controller

Product Details
Customization: Available
Certification: CE/ISO9100/So14001
Output Power: >1000W
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (31)
  • Variable Frequency Drive VFD Constant Pressure Water Pump Controller
  • Variable Frequency Drive VFD Constant Pressure Water Pump Controller
  • Variable Frequency Drive VFD Constant Pressure Water Pump Controller
  • Variable Frequency Drive VFD Constant Pressure Water Pump Controller
  • Variable Frequency Drive VFD Constant Pressure Water Pump Controller
  • Variable Frequency Drive VFD Constant Pressure Water Pump Controller
Find Similar Products

Basic Info.

Model NO.
B603 Series
Grid Type
off-Grid Inverter
Output Type
Multiple
Circuit Topologies
Full-Bridge Type
Nature of Wave String
Square Wave Inverter
Type
DC/AC Inverters
Output T Type
Single/Triple Phase 220V/380V
Power
0.75kw~350kw
Frequency
50Hz/60Hz
Phase
Single
Power Source
Electric Power
Transport Package
Pallet/Carton
Specification
CE/ISO9001/IS014001
Trademark
BEDFORD
Origin
Guangzhou
Production Capacity
5000 Units/Month

Product Description

Variable Frequency Drive VFD Constant Pressure Water Pump Controller



Why Always
 BEDFORD???
1.Professional--Twenty years Professional Power Inverter Export, eight years manufacturer Experience
2.Hi-tech--Advanced R&D Team
3.Certifications--Applied with CE, ISO 9001, ISO14001
4.Good quality--BEDFORD Brand, Patent products.
 

 

 

Integrated Intelligent variable frequency constant pressure water supply equipment pump controller

To solve the problem of insufficient water presure field.

 
Applicable to school,hospital,villas,large commuity,low-rise residential and other occasions

 water pump inverter years of factory producing pump inverter


 Features:
1.automatically control and constant water pressure

2.Setting pressure through keypad directly

3.Built-in terminal for pressure sensor,flow sensor and water level switch

4.Built-in PID control method can realize none load shut down(sleep mode)

5.No need power distribution cabinet and PLC to realize Muti-Pump auto switch-over and linkage operation

6.Water lack protection and water recovery restart

7.Power-on restart

8.Master fault shift automatically

9.Nought flow shut down protection actives when no water consuming, auto start and stop

10.When multi-pump working, regularly switch over maste pump and prevent from pump rusting

11.Real-time fault parameter record is ready for fault analysis

12.Work hour auto accumulative total is easy for enerfy saving analysis and equipment maintenance

13.Complete protection functions and reliability for water pump inverter, including under voltage, over voltage, over current, over hear and so on
 


PREFACE
With high quality, multi-function, low noise and strong commonality etc. characteristics, B603 series intelligent constant pressure water pump inverter is suitable to full-automatic operation;
Special design based on users' needs, suitable for all kinds of applications, easy operation;
According to the water condition to supply constant pressure water without manual operation after parameters were set correctly.
Stop running automatically when no one use of water; Alarm automatically when fault occurred;
Alternate running automatically in the multiple pump system, prolong the service life of pumps;
Adapt to many kinds of input pressure signals;
Can be connected to upper computer through RS485 communication function for centralized monitoring.
 
ENVIRONMENTAL REQUIREMENT
1 Environment temperature range: -10 degree~+40 degree. Controller will be derated if ambient temperature exceeds 40degree.
2 Prevent rain drops, moist environment, oil fog, salt erosion, corrosive gas, etc.
3 Prevent direct sunlight, keep away from radiation source.
4 Prevent violent vibration or sudden impact.
5 Lower than 1000m installation altitude, water pump inverter will be deratd when the altitude is higher than 1000m.
 
    Products
Can't wait to know more about our Company, Products, Price, Packing, Shipping? Dear FriendsLet's talk NOW !!!!!
B603B series water pump inverter 2001 2002   4001 4002 4003
Voltage 1φ200V-240V 3φ380V-440V
Capacity(KW) 0.75 1.5   0.75 1.5 2.2
Rated output vol.(V) 3φ 220V-240V 3φ 380V-440V
Rated output current A 4.5 7.0   2.5 3.7 5
Control mode Sensorless Vector Control (SVC), V/F Control
Output frequency range Maximum 50Hz
Frequency resolution Analog input volume:0.1Hz
Overloading capacity Rated output current:  150%-1 minute
                  180%-10 seconds
Transmitter signal 4~20mA
No.of V/F Patterns Vector curve, Random V/F curve
Location Indoor(protected from corrosive gases and dust)
Ambient temperature -10~40°C(If beyond the allowable degree,one degree will Derogate 5% output current)
Storage temperature -40~60°C
Environmental temperature 95%(without dew gather)
Vibration 2M/S2 (0.2G)
Protection rate IP54