B603D/B2 series intelligent constant pressure water supply controller is suitable for full-automatic operation, with characteristics of high quality, multi-functional, low noise and strong commonality etc.
There are no special demands for peripherals, it mainly use normal components, for example: Water detection use transducer, transmitter (include water level transmitter, temperature transmitter, etc. ) or inductive remote transmission pressure gauge, with output of 4~20mA, 0~5VDC and 0~10 VDC standard signal.
Power range:
I B603A series Intelligent constant pressure pump controller
Single phase 220V input, 3 phase 220V output: 1HP-7HP(0.75KW-2.2KW)
Three phase 220V input, 3 phase 220V output: 4HP-75HP(3.7KW-55KW)
Three phase 380V input, 3 phase 380V output: 1HP-470HP(0.75KW-350KW)
II B603B series Intelligent constant pressure pump controller(water proof)
Single phase 220V input, 3 phase 220V output: 1HP-3HP(0.75KW-2.2KW)
Three phase 380V input, 3 phase 380V output: 1HP-3HP(0.75KW-2.2KW)
Function characteristics:
Multi-pump control: Can realize 1 master and max. 5 auxiliaries combine work
Sleep function: Sleep down when have no water consumption, to earn a better energy saving
Freeze-proofing function: Suitable to low temperature area, prevent pump from freezing
Anti-clogging function: Take precaution against pipe clogging and clean the pipe dirt
Power on restart: Running automatically when power on
Master fault shift automatically: Keep on working when the master break down
Alternate running: Balance every pump's running time, prolong service life of the whole unit machine
Day-part function: 3 independent day-part control, up to 7 day-part achieved when define separated
Two running mode: Synchronous control mode, master-slave control mode
Terminal control mode: Terminal run/stop, manual/auto control, electronic contact gauge control
Various of water supply fault alarm function: High-pressure, low-pressure, low-level, transducer error etc.
As many as 22 kinds of fault protection function: Over-current, over-voltage, low-voltage, phase-failure, over-load etc.
List part item for reference.
B603B2 series |
200 1 |
200 2 |
200 3 |
4 00 1 |
4 00 2 |
4 0 03 |
Volt a ge |
1 φ 200V-240V |
3 φ 380 V- 440 V |
Capacity(KW) |
0.75 |
1.5 |
2.2 |
0.75 |
1.5 |
2.2 |
Rated output vol.(V) |
3 φ 220V-240V |
3 φ 380V-440V |
Rated output curre n t A |
4. 5 |
7.0 |
10 |
2.5 |
3.7 |
5 |
Control mode |
Sensorless Vector Control (SVC), V/F Control |
Output frequency range |
Maximum 5 0Hz |
Frequency resolution |
Analog input volume:0.1Hz |
Overloading capacity |
Rated output current : 150%-1 minute
180 %- 10 seconds |
Transmitter signal |
4~20mA |
No.of V/F Patterns |
Vector curve, Random V/F curve |
Location |
Indoor(protected from corrosive gases and dust) |
Ambient temperature |
-10~4 0°C( If beyond the allowable degree,one degree will Derogate 5% output current) |
Storage temperature |
-40~6 0°C |
Environmental temperature |
95%(without dew gather) |
Vibration |
2M/ S 2 (0.2G) |
Protection rate |
IP 54 |
Obtained Certificate: