Application: | General Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | V/F Control Transducer |
Switch Mode: | PWM Control |
Main Circuit Type: | Voltage |
Voltage of Power Supply: | DC |
Customization: |
---|
Suppliers with verified business licenses
Maximum input DC voltage | 800VDC |
Recommended DC input voltage range | 420~720VDC |
Recommended input working voltage | 540VDC |
The number of Input port | 1 |
Rated output voltage | 3AC 380V |
Output frequency range | 0~600Hz |
Cooling method | Air cooling |
altitude | This controller should be installed with altitude of lower than 1000m. It will be degraded when the altitude higher than 1000m. For details, rated output current should be degraded 1% for every 100m |
Standard | CE |
Maximum input DC voltage | 410VDC |
Recommended DC input voltage range | 220-370VDC |
Recommended input working voltage | 305VDC |
The number of Input port | 1 |
Rated output voltage | 3AC 220V |
Output frequency range | 0~600Hz |
Cooling method | Air cooling |
Altitude | This controller should be installed with altitude of lower than 1000m. It will be degraded when the altitude higher than 1000m. For details, rated output current should be degraded 1% for every 100m |
Standard | CE |
Suppliers with verified business licenses