W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output

Product Details
Customization: Available
Application: Single-phase Transducer
Output Type: Single
Still deciding? Get samples of US$ 103/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (31)
  • W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output
  • W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output
  • W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output
  • W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output
  • W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output
  • W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Installation Instructions
  • Certifications
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Model NO.
W713B-20XX
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Constant Torque Universal Type
Brand
Starpower IGBT
Moisture Protection
IP54
Color
Black or OEM
220V Power Range
0.37kw-3.0kw
Working Voltage
220V Plus or Minus 15%
Transport Package
Carton
Specification
0.37kw -3.0kw
Trademark
BEDFORD
Origin
Guangzhou, China
HS Code
9032899099
Production Capacity
50000/Month

Packaging & Delivery

Package Size
33.00cm * 31.00cm * 29.00cm
Package Gross Weight
5.000kg

Product Description


 
Product Description
W713B series products are not only the integrated intelligent controller  designed for water pump, but also the intelligent controller designed for the central air-conditioning water circulation system to realize the differential constant pressure control.
W713B Intelligent controller has superior performance and rich use function, can meet the requirement of water supply and drainage on various occasions and improve the quality of water supply system. The  product  adopts  the  control  method of one pump and one variable frequency controller, which can effectively extend the motor service life;  the  controller  system  supports  max.6  pumps  linkage work, meet the customers' operating requirements.
With high quality, multi-functional, low noise and strong commonality etc. characteristics, W713B multi-function energy-saving controller is suitable to full- automatic operation.
Suitable for various constant pressure/constant differential pressure/constant temperature/constant differential temperature water supply applications.
After parameters were set correctly, the system can operate automatically with constant pressure/constant differential pressure/constant temperature/constant differential temperature according to the water consumption without manual operation;
Alternate running automatically in the multiple pump system, prolong the using life of pumps.
Restart automatically when power recovery
Stop running automatically when no water consumption;
Alarm automatically when faults occurred;
Suitable for various pressure signals input.
  •  
PRODUCT INTRODUCTION
    1. Features
      1. Input & Output
        • Input Voltage Range: 1 PH 220V
        • Input Frequency Range: 47~63Hz
        • Output Voltage Range: 1 PH 220V
        • Output Frequency Range: 50/60Hz
      2. I/O Features
        • Digital Switch Input: 4 input
        • Analog Signal Input: AI1: 0~10V or 0/4~20mA input; AI2: 0~10V or 0/4~20mA input
        • Relay Output: Two pair of switch output
      3. Function Characteristics
        • Multi-Pumps Control Function: Max.6 pump linkage water supply
        • Sleep Function: Sleep down when have no water consumption, to earn a better energy saving
        • Freeze-Proofing  Function:  Suitable  to  low  temperature  area, prevent pump from freezing
        • Anti-clogging Function: Take precaution against pipe clogging and clean the pipe dirt
        • Power On Restart: Running automatically when power recover from power failure.
        • Master Fault Shift Automatically: Keep on working when the master breakdown
        • Alternate Running: Balance every pump's running time, prolong service life of the whole unit machine
        • Control Mode: Constant pressure, constant differential pressure, constant temperature,constant differential temperature,manual
        • Linkage Mode: Synchronize, master-slave, big-small pump combination, one duty one standby,one VFD drives two pump (in conjunction with control electric cabinet).
        • Terminal Control Mode: Electronic contact gauge control, manual/auto control,terminal run/stop, automatic water level control,one VFD drives two pump fault input.
        • Start/Stop Independent Control: In the water supply system,each inverter start/stop control can be set independently.
        • Various of Water Supply Fault Alarm Function: High-pressure, low-pressure, low-level, transducer error etc.
        • Multiple Fault Protection Function: Over-current, over-voltage, low-voltage, phase- failure,over-Load etc.
        • Scalability: Can be connected to our company touch screen(HMI)

      4.  
               2.Model Specification
W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output                  3.Selection Guide



W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output
Product Parameters
Model
 
Rated Output Current (A)
 
Adapted to Three Phase Motor Recommended Single Phase Motor (Not suitable for the motor that Starting and Running Capacitor in separate)
Motor Wire is connected to Inverter U, V, W terminal Power Wire is connected to Inverter R/L, S/N terminal;
Motor Wire is connected to Inverter V, W terminal
W713B-2001 4.5 0.75kW 0.37kW
W713B-2002 7.0 1.5kW 0.75kW
W713B-2003 10.0 2.2kW 1.1kW
W713B-2004 13.0 3.0kW 1.5kW
W713B-2005 17.0 3.7kW 2.2kW
W713B-2007 25.0 5.5kW 3.0kW
Parameter Setting
Enter debug passwords b00.00=65535, enter into br-06 Group Parameter
Three Phase Motor: b06.17=0 (Factory Setting), b06.18=1 (Factory Setting), b06.19=1 (Factory Setting)
Single Phase Motor: b06.17=1, b06.18=0, b06.19=0
W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output

 
Detailed Photos

W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V OutputW713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V OutputW713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V OutputW713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V OutputW713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V OutputW713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V OutputW713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output

 
Installation Instructions

 

           
 External Dimensions
W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output
             5.Environmental Requirements

W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output
Certifications

 

W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output
Packaging & Shipping

 

W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V OutputW713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V OutputW713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output
Application
W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output


 
Company Profile

 

W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V OutputW713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output
W713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V OutputW713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V OutputW713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V OutputW713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V OutputW713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V OutputW713b Backpack Mounted Pump Dedicated VFD with Single Phase 220V Output


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now