Customization: | Available |
---|---|
Application: | General Transducer |
Output Type: | Single |
Still deciding? Get samples of US$ 238/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Function Name | Action | Factory setting |
Sleep Function | No water consumption pump decelerates to the lower limit and after a detection then sleep down. Until the pressure below settings, master wake up automatically. | valid |
Restarts After Power on | Power off during running, it restarts when power on again | invalid |
Anticlogging Function | Just designed for single pump, the pump run REV/FWD alternate. | invalid |
Day-Part Control | Devide one day into several day-part to run a private pressure respectively. Considered input side water pressure limit, once input water pressure is less than setting pressure, stop running; while up to setting, recover running. | invalid |
Terminal Run/Stop | Can be lead to external switch from terminal. When switch on, pump run and maintain a setting constant pressure; when switch off, pump stopped. | invalid |
Manual/Auto Control | Can be lead to external switch from terminal. When switch on, pump run with full-frequency; when switch off, return to variable frequency constant pressure control. | invalid |
Electric contact Control | Two terminals switch on COM instruct the controller to accelerate and decelerate respectively. Can used for realize the pump running in a switch setting pressure range. | invalid |
Model No. | Rated Input Voltage(V) | House Power(HP) | Rated Output Current(A) | Motor Power(KW) |
B601D-2001 | 1AC: 220V -15%~+15% |
1.0 | 5.3 | 0.75 |
B601D-20015 | 1.5 | 6.5 | 1.1 | |
B601D-2002 | 2 | 9.6 | 1.5 | |
B601D-2003 | 3 | 14 | 2.2 |
Model (kW) |
A (mm) | B (mm) | H (mm) | W (mm) | D (mm) | Installation Hole | |
Installation Dimension | External Dimension | ||||||
0.75~2.2 | 110 | 169.6 | 179.6 | 120.1 | 150.3 | 4.0 |