Air-Conditional Chiller Pump Controller B605D Series 220V (IP20)

Product Details
Customization: Available
Application: High-performance Transducer, Three Phase Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (31)
  • Air-Conditional Chiller Pump Controller B605D Series 220V (IP20)
  • Air-Conditional Chiller Pump Controller B605D Series 220V (IP20)
  • Air-Conditional Chiller Pump Controller B605D Series 220V (IP20)
  • Air-Conditional Chiller Pump Controller B605D Series 220V (IP20)
  • Air-Conditional Chiller Pump Controller B605D Series 220V (IP20)
  • Air-Conditional Chiller Pump Controller B605D Series 220V (IP20)
Find Similar Products

Basic Info.

Model NO.
B605D
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type
Brand
Bedford
Color
Blue
IP
20
Warranty
1 Year
Certificate
Ce, ISO 9001, ISO14001
Voltage
190~250V
Transport Package
Carton
Specification
0.75kw~350kw
Trademark
BEDFORD
Origin
Guangzhou, China
Production Capacity
5000 Units/Month

Product Description

Air-Conditional Chiller Pump Controller
B605D Series(220V) 

Air-Conditional Chiller Pump Controller B605D Series 220V (IP20)
Product Description:
B605 series controller is specially designed for central air-conditioning water circulation system to realize constant pressure differential control. It can confirm the system to adapt to the change of air-conditioning load, with the advantage of rapid reaction, little influencing on temperature and humidity, ensuring the balance of the system, effecient energy-saving and so on.

Input Voltage/Output Power Range:
Single phase 220V input,3 phase 0-220V output: 1HP-3HP(0.75KW-2.2KW)
Three phase 220v input,3 phase 0-220v output:1~70HP(0.75~55KW) 


Applications:
Central air conditioning circulating system.
                      Air-Conditional Chiller Pump Controller B605D Series 220V (IP20)


Features:
1. Relay Output: 2 Outputs.
2. Professional design based on users' needs, suitable for differential pressure control, simple operation.
3. Running automatically when power on.
4. Programmable Analog Input:
   AI1:0~10V or 0~20mA input
   AI2:0~10V or 0~20mA input
5. Multi-Pump Control: can realize 1 master and 5 slaves combine work at most.
6. Constant Differential Pressure Control: PID, control based on feedback source of (AI1-AI2).
7. Alternate running balance every pump's running time, prolong service life of the pump.
8. Verious of water supply fault alarm functions:high pressure, low pressure, low level, transducer error etc.
9. As many as 22 kinds of fault protection functions: over current, over voltage, low voltage, phase failure, over load etc.
 
Dimension:
Air-Conditional Chiller Pump Controller B605D Series 220V (IP20)

Air-Conditional Chiller Pump Controller B605D Series 220V (IP20)

Keypad Description:
Air-Conditional Chiller Pump Controller B605D Series 220V (IP20)

Daily Maintenance:

In order to prevent the fault and prolong the service life of the controller, user shall daily
inspect the controller. The following table indicates the inspection content:
Air-Conditional Chiller Pump Controller B605D Series 220V (IP20)



 Replacement of Wearing parts:

  Fans and electrolytic capacitors are wearing parts; please make periodic replacement to ensure
long term, safety and failure-free operation. The replacement periods are as follows:
1. Fan: must be replaced when using up to 20,000 hours;
2. Electrolytic capacitor: must be replaced when using up to 30,000~40,000 hours.

 

 

 